<LOGO>
FM Transmitter Measurement Report
Created: 2024-12-21 17-26-51
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
101.20 MHz 3/5, 54 dBuV NOSTALGI
Pilot RDS Phase Difference
6.6 kHz 3.9 kHz 1 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
12 kHz 69 kHz 11062 0,0633
Modulation Power
Limit Measuring Tolerance
10,0 dBr 3,0 dBr
MIN AVE MAX % above 13,0 dBr
4,6 dBr 5,41 dBr 6,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"NOSTALGI" F218 0 (No PTY) 1 0 1 2 17:26, 21.12.2024
RT
"NOSTALGIE : AXEL BAUER - Et La Lumi "
AF EON
90.4, 90.5, 91.9, 93.7, 95.6, 100.1, 100.2, 101.2, 106.2, 106.3, 106.8 MHz -
FM Scope Station: 101.20 MHz, signal: 3/5 (54 dBuV) Max at: 69 kHz MIN: 12 kHz % above 75 kHz: 0,0633 Acquired: 2024/12/21 17:25:47 Total samples: 11062 Equivalent time: 0:09:13 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 6,2 dBr MIN: 4,6 dBr AVE: 5,41 dBr % above 13,0 dBr: 0,0 Last value: 5,2 dBr (2024/12/21 17:25:46) Station: 101.20 MHz, signal: 3/5 (54 dBuV) 17:14 17:16 17:18 17:20 17:22 17:24 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality